Alarm information:
Cause |
Diagnostic on negative result of configuration from FB.CFG |
<code> |
Error code: •-1 = Initialization not performed •1 = FB.CFG file does not exist (not present on the CF) •2 = Unknown command •3 = Invalid parameter •4 = Invalid position •6 = Necessary information missing •7 = Multiple definition •14 = Multiple or missing ws file definition •15 = Allocation failed •16 = Missing ws that must instead be present at switch on •21 = Timeout during parameterization or execution of a command •22 = Command execution of invalid code •23 = Error during execution of a command •24 = Board not ready to be parameterized •25 = Incorrect board configuration •26 = Too many commands to be stored to restart the board •27 = Collision in data definition •28 = Invalid index |
<line> |
Line number where the error was encountered |
Output condition |
Anomalies in the interpretation of the FB.cfg file |
Effect |
Communication not active |
What to do |
Check network |
Alarm mask |
am[50].6 |
Alarm par prominent |
No |
Alarm type |
|
Notes |
More information about this alarm can be obtained by querying the operating system report via the mreport -a directive |