Please enable JavaScript to view this site.

Alarm information:

Cause

EtherCAT communication diagnostic

<int>

Ethernet interface number

<code>

Error codes:

0x0001 = Link error

0x0002 = I/O blocked after link error (I/O reset required)

0x0004 = link error (redundancy adapter)

0x0008 = missing frame (redundancy mode)

0x0010 = send resources exhausted (I/O reset required)

0x0020 = watchdog enabled

0x0040 = Ethernet driver (miniport) not found

0x0080 = I/O reset enabled

0x0100 = At least one device in 'INIT' state (but only after ECAT line started correctly)

0x0200 = At least one device in 'PRE-OP' state (but only after ECAT line has started correctly)

0x0400 = At least one device in 'SAFE-OP' state (but only after ECAT line has started correctly)

0x0800 = At least one device indicates an error state

0x1000 = DC not synchronized

Output condition

EtherCAT network management anomalies

Effect

Communication not active

What to do

Check network

Alarm mask

am[50].4

Alarm par prominent

Yes

Alarm type

Autodia

Notes

This alarm is generated if enabled via the variable fb_flag. By default, the equivalent alarm 82 is generated, which, being major alarm, drops the power set.

If a command modifies the status of the EtherCAT network from OPERATIONAL(ECAT_SET_STATE), the alarm can be delayed(ECAT_SLAVE_DISCON_TIME)

 

  