Allows the language for alarm stack and alarm history management to be set.
At switch on, RTE according to the selected language searches the CF for the presence of alarm files related to the selected language.
These files are SYS_ALARM_FILE (contained in etc/hw/rte/alsys) for system alarms and USER_ALARM_FILE for user alarms. They must be present on the CF.
Through project configurator it is possible to specify both the language and the relative path to the text files on the development PC.
Syntax |
LANGUAGE n |
---|---|
n |
0x10 = (Italian IT) 0x09 = (English EN) 0x07 = (Deutch DE) 0x0A = (Spanish ES) 0x0C = (French FR) 0x16 = (Portuguese PO) 0x19 = (Russian RU) 0x12 = (Korean KO) 0x04 = (Chinese ZH) 0x13 = (Duth NL) |
Attributes |
Keyword not mandatory. If absent, language "NEUTRAL", i.e. English, is selected |
WARNING: This keyword is automatically generated by project configurator.
Project Configurator --> General --> System
Project Configurator --> General --> Alarms --> User Files
NOTE: This keyword can be overridden by the presence of the override.cfg file present on the CF.
NOTE: The ETC/RTE/ALSYS folder of the RDE3 distribution contains the language translation files of the system alarms.