Alarm information:
Cause |
Error while connecting a device |
<ch> |
CAN channel number |
<node> |
Device identification number in the configuration file |
<code> |
Error code: •1 = Timeout on configuration command, no response •2 = VENDOR_ID of device incorrect, does not match value in configuration file •3 = PROD_CODE of device incorrect, does not match value in configuration file •4 = REVISION of the incorrect device, does not match the value in the configuration file •6 = Size of output data (from_rbx) of device incorrect, size too small •7 = Size of input data (to_rbx) of device incorrect, size too small •10 = Error writing PACHET_RATIO data of the device |
Output condition |
|
Effect |
Communication with device not enabled |
What to do |
Correct configuration file according to the error encountered |
Alarm mask |
am[50].17 |
Alarm par prominent |
Yes |
Alarm type |
|
Notes |
More information about this alarm can be obtained by querying the operating system report via the mreport directive |