Permette di leggere oggetti COE collegati via Fieldbus.
•COE_ROBJ -H: Visualizza la lista dei tipi di dato
•COE_ROBJ -AC hhhh llll: Visualizza la stringa per il codice errore di ritorno (0xhhhhllll)
•COE_ROBJ -T datatype nws objCode subIndex [-L n] [-R idx | -RR idx | -SR idx ]
Sintassi |
COE_ROBJ -H COE_ROBJ -AC hhhh llll COE_ROBJ -T datatype nws objCode subIndex [-L n] [-R idx | -RR idx | -SR idx ] |
---|---|
-T datatype |
Tipo di dato: 1 = BOOLEAN 2 = INTEGER 8 3 = INTEGER 16 4 = INTEGER 32 5 = UNSIGNED 8 6 = UNSIGNED 16 7 = UNSIGNED 32 8 = REAL 32 9 = VISIBLE_STRING 10= OCTET_STRING 11 = UNICODE_STRING 12 = TIME_OF_DAY 13 = TIME_DIFFERENCE 15 = DOMAIN 16 = INTEGER 24 17 = REAL 64 18 = INTEGER 40 19 = INTEGER 48 20 = INTEGER 56 21 = INTEGER 64 22= UNSIGNED 24 24= UNSIGNED 40 25= UNSIGNED 48 26= UNSIGNED 56 27= UNSIGNED 64 30 = BYTE 45 = BITARR8 46 = BITARR16 47 = BITARR32 NOTA: Per avere la lista dei tipi di dato utilizzare il seguente comando: COE_ROBJ -H. |
nws |
Numero di workstation |
objCode |
Oggetto |
subIndex |
Subindex |
-L n |
Numero di byte massimi visualizzati in caso OCTET_STRING. (opzionale) |
-R idx |
Indice registro intero in cui memorizzare il valore dell'oggetto specificato |
-RR idx |
Indice registro reale in cui memorizzare il valore dell'oggetto specificato |
-SR idx |
Indice registro stringa in cui memorizzare il valore dell'oggetto specificato |
Note |
Nel caso in cui venga dato un comando illegale si avrà una risposta del tipo: ERROR on SDO : 0x<code> dove <code> potrà assumere i seguenti lavori: 0503 0000 = Toggle bit not aternated 0504 0000 = SDO protocol timed out 0504 0001 = Client / Server command specifier not valid or unknown 0504 0002 = Invalid block size (block mode only) 0504 0003 = Invalid sequence number (block mode only) 0504 0004 = CRC error (block mode only) 0504 0005 = Out of memory 0601 0000 = Unsupported access to an object 0601 0001 = Attempt to read a write only object 0601 0002 = Attempt to write a read only object 0602 0000 = Object does not exist in the object dictionary 0604 0041 = Object cannot be mapped to the PDO 0604 0042 = The number and lenght of the objects to be mapped would exceed PDO lenght 0604 0043 = General parameter incompatibility reason 0604 0047 = General internal incompatibility in the device 0606 0000 = Access failed due to an hardware error 0607 0010 = Data type does not match, length of service parameter does not match 0607 0012 = Data type does not match, length of service parameter too high 0607 0013 = Data type does not match, length of service parameter too low 0609 0011 = Sub-index does not exist 0609 0030 = Value range of parameter exceed (only for write access) 0609 0031 = Value of parameter written too high 0609 0032 = Value of parameter written too low 0609 0036 = Maximum value is less than minimum value 0800 0000 = General error 0800 0020 = Data cannot be transferred or stored to the application 0800 0021 = Data cannot be transferred or stored to the application because of local control 0800 0022 = Data cannot be transferred or stored to the application because of the present device state 0800 0023 = Object dictionary dynamic generation fails or no object dictionary is present (e.g. object dictionary is generated from file and generation fails because of an file error) NOTA: Per avere la stringa di errore partendo dal codice di utilizzare il comando: COE_ROBJ -AC hhhh llll dove hhhh e llll rappresentano i quattro digit alti (hex) del codice di errore mentre llll quelli bassi. |