Validity: Rule, Task

This predefined variable allows you to set a timeout after which, at boot time, RTE switches to run mode even if the VALID_DATA_TRD (valid fieldbus location information) variable is different from the one specified in the configurator.

Syntax

REAL valid_data_to [n]

n

Value in seconds. (optional, default 0)

At switch on in fact RTE, before switching to run mode, waits until the valid_data_trd variable is equal to the configured transducers or the timeout indicated by the VALID_DATA_TO predefined variable has expired.

Use the configurator to set the parameter:

valid_data_to_zoom25

Example

 

  