Date: October 30, 2015

Bios: 2.5.0, Os: 14.5.13, RLib: 4.5.2, RLibpp: 2.0.0, MiniXML: 1.3.1

Derived from : RTE 34.15.12

Note: available for controls with PPC-G2 cpu and for controls with PPC-P2020 cpu.

Note: suite with >= RDE3.11.8

Note: suite with >= RC3E v33.5.17

Note: suite with >= RPE v1.6.0

build 8

CORRECTION:(Robox Control Board AS3031.xxx) : Fixed error on RCB photo management using absolute translators

build 7

CORRECTION: ETHIP: eliminated slowdown in message exchange.

IMPLEMENTATION: SYS_FLAG: Added bits 25 and 26 to SYS_FLAG to dump on report messages received/sent via EthIP. Dumping occurs only for the number of messages specifiedat1 in SYS_COUNT.

build 6

VARIANT: CO_CONTROLWORD_OM: also enabled bit 0x400 among user writable bits a can/coe controlword. Now the mask of user writable bits is 0xFD70.

CORRECTION: CAN FLOAT : corrected alignment problem that was happening by mapping in pdo a float variable not on the first or fourth byte.

build 5

IMPLEMENTATION: CPU_TEMP: Added read only PR(32) parameter showing cpu temperature in degrees.

build 4

CORRECTION: MODBUS TCP CLIENT: Verified real connection status on client commands to avoid returning TX error. This problem was happening if, for example, the server closed the connection.

CORRECTION : MVA_TO_N_CJ: Generated 2800 DOUBLE POSITION alarm illegally.

CORRECTION : MVA_ZC RCB(Robox Control Board AS3031.xxx) : Avoided forcing photo hw using input channels 10-11-12 14-15-16. The problem was encountered using one of the above channels with the endat type motor transducer.

CORRECTION: MVA_TO_N, MVA_TO_N_V, MVA_TO_N_CJ: Fixed error that occurred if the first axis of the array was an axis declared NOT PRESENT. Fixed handling also in case all axes are of type NOT PRESENT

build 3

VARIANT: MODBUS: Improved handling of message dumps in the report.

build 2

IMPLEMENTATION: MODBUS: Added in report message dump in modbus client communication using SYS_FLAG and SYS_COUNT

IMPLEMENTATION: BCC3: Added commands 316 to 320 (robox reserved)

IMPLEMENTATION: SYS_FLAG bit 13: Benchmark

IMPLEMENTATION: BCC3: Added management for BCC3 commands intended for RPE

IMPLEMENTATION: MODBUS server Holding register: Added possibility to associate predefined variables read only to holding registers

VARIANT: Alarm 9104: abialtated diagnostic only after ECAT SO transition

VARIANT: started digital filter handling after ready transducer signal

CORRECTION: Toughened EDGE variable handling on LIVE changes.

build 1

IMPLEMENTATION: PCT: Planar Compensation Table: Added management for axis nonlinearity compensation.

 

  