Please enable JavaScript to view this site.

Alarm information:

Cause

Error encountered during CAN channel configuration step

<ch>

CAN channel number (index starting from 0)

<code>

Error code:

-3 = Missing field bus manager file (CODMvvrr.ufw/CODMvvrr.o86/SCDMvvrr.ufw) in the /F@ partition of the flashcard

-2 = Missing PFLMvvrr.o86 file in the /F@ partition of the flash card or communications board firmware loader not started

-1 = Initialization never performed

0 = Configuration successfully terminated

1 = COCn.CFG configuration file not present on the flash card

2 = Unknown command present in COCn.CFG file

3 = Illegal parameter present in COCn.CFG file

4 = Canbus board in illegal location in RBXM rack or can command used illegally

6 = Missing necessary information

7 = Multiple definitions

14 = Workstation information missing or defined multiple times

15 = Memory allocation problems

16 = No workstation that MUST be present at switch on

21 = Expired time-out during execution of a parameter command

22 = Illegal code on execution command

23 = Error on execution command

24 = Canbus board not yet ready to be parameterized

25 = Canbus board is not properly parameterized to operate

26 = Too many commands to store to reparameterize the board on the fly (max 180 SDOs)

Output condition

Presence of can board

Effect

Failure to configure the CAN channel

What to do

Check the reported code and act accordingly

Alarm mask

am[49].22

Alarm par prominent

Yes

Alarm type

Autodia

Notes

It is possible to obtain more information about this alarm by querying the operating system report via the report (or mreport) directive

Additional information in system report

Using the mreport directive, diagnostic messages such as:

in which <code> will be the same as described above, while <par> is used to further specify the alarm type as below:

<code>

<par>

Description

1

-

"'COCn.CFG file not found for CANINT:n"

2

-

"Can Unknown command 'text' - line<%d> file COCn.CFG"

3

-

"Can Bad parameter(s) 'text' - line<%d> file COCn.CFG"

4

<0

"Can Board (%d) in wrong slot (No Interrupt)" N.B.Le schede canbus devono essere sempre inserite nei primi 7 slot

>=0

"Can Command in wrong place '%s' - line<%d> file COCn.CFG"

6

-

"Can Missing Obligatory Information into file COCn.CFG"

-1

"Can Missing BoardInfo or Workstation Info into file '%s'"

-2

"Can Not All ws were not Logical Defined into file '%s'"

7

-

"Can Multiple definition '%s' - line<%d> file '%s'"

14

-

"'RBXCNET.WSn' file not found or multiple definition for CANINT:%d"

15

-

"%d"

0

"allocation fault on buffer info ws creation"

1

"allocation fault on write pdo"

2

"allocation fault on write sdo"

3

"allocation fault on read pdo"

4

"allocation fault on read sdo"

5

"allocation fault on error string generation"

16

-

"Can Missing Needed Can WS <%d> on Channel<%d>"

21

-

"%d"

-1

"can board configuration timeout"

1

"SDO command timeout"

2

"NMT command timeout"

3

"data available timeout"

24

-

"Can Channel<%d> not ready to accept parameter"

25

-

"%d"

2

"hardware can not trasmit" (Check the connection/baud rate)

3

"station can not be configured"

26

-

"Can Too many command to store to restart node <%d>"

 

  