Alarm regarding the progress of the task of managing Modbus client connections directed to AXL_F_BK_ETH heads.

Alarm information:

Cause

Lower frequency of rules and/or ladder task (HP, MP, synchronous) and/or periodic rule and/or asynchronous rule (interrupt, input, etc.) than expected

<task>

Task number

Output condition

 

Effect

Phoenix Contact Modbus client task execution frequency is less than the theoretical one

What to do

Verify that the above tasks are written as linearly and concisely as possible.

Optimize execution timings where possible by using local support variables.

Verify that the execution frequency of the rules is not higher than what is really needed by the application

Alarm mask

am[48].19

Alarm par prominent

No

Alarm type

Autodia

Notes

 

 

  