Alarm information:
Cause |
Found divergence between the current hardware configuration of the Robox module and the one provided in the rhw.cfg file |
|
<code> |
Error code: •1 = Reserved •2 = Less boards than desired •3 = More boards than desired •4 = Problems when writing RHW.CFG file to flash eprom •5 = RHW.CFG file missing •6 = RHW.CFG file with syntactic errors •7 = Different board layout in the basket than desired •8 = RSW.CFG file with syntactic errors •9 = RSW.CFG file missing |
|
Output condition |
|
|
Effect |
Unable to use the Robox module |
|
What to do |
Check the boards present in the basket. Check the rhw.cfg file |
|
Alarm mask |
am[0].8 |
|
Alarm par prominent |
No |
|
Alarm type |
||
Notes |
In case of an alarm with code 2, with connected Axioline modules of safety type, check that in the file /F@/FIBO.INI is present (if not present, the content should be added to the queue of the file):
|