Please enable JavaScript to view this site.

Alarm information:

Cause

This message is sent if the EtherCAT application rejects the value of SyncManOutPar.CycleTime (item "0x1C32 0x02") or SyncManInpPar.CycleTime (item "0x1C33 0x02") during the EtherCAT state transition from PRE_OPERATIONAL to SAFE_OPERATIONAL state.

The value of the communication cycle period (CycleTime in us) is calculated by the application firmware from the value of entry "0x1C32 0x02"

<axis>

Axis number (1-32)

Output condition

Emergency: FF80h 01h nnnn4004FFh

Effect

In this situation, the EtherCAT slave interface remains in the PRE_OPERATIONAL state

What to do

 

Alarm mask

am[<axis>].9

Alarm par prominent

 

Alarm type

ExtDev

Notes

From RTE v34.11.3 emergency messages are handled as alarms: to disable the new handling act on bit 0 of the variable sys_cfg.

Alarm related to the SPIMD20 device connected on the EtherCAT network

 

  