Alarm information:

Cause

This message is sent if CpuFld detects failure of CpuDrv communication conditions during normal EtherCAT life

<axis>

Axis number (1-32)

<name>

Device type name (IMD, EC2-A).

From RTE 34.28.04, the device name is EC Drive

Output condition

Emergency: FF80h 01h 0000C10301h

Effect

In this situation, the EtherCAT Slave interface transitions to the PRE_OPERATIONAL state and rejects the higher state transition to the PRE_OPERATIONAL state

What to do

 

Alarm mask

am[<axis>].9

Alarm par prominent

 

Alarm type

ExtDev

Notes

From RTE v34.11.3 emergency messages are handled as alarms: to disable the new handling act on bit 0 of the variable sys_cfg.

From RTE v34.24.0 the alarm is also used for the EC2-A drive.

Alarm related to the SPIMD20 or EC2-A device connected on the EtherCAT network.

Alarm cannot be deleted.

From RTE 34.28.04 the device name is EC Drive

 

  