Please enable JavaScript to view this site.

Alarm information:

Cause

This message is sent if CpuDrv detects an unexpected internal control selection (e.g., when in ModeOfOperation Manufacturer Specific Autotuning Test Mode the OperationEnabled state of DSP402 is requested without the test being selected)

<axis>

Axis number (1-32)

<name>

Device type name (IMD, EC2-A).

From RTE 34.28.04, the device name is EC Drive

Output condition

Emergency: 6100h 01h 0000481000h

Effect

 

What to do

 

Alarm mask

am[<axis>].9

Alarm par prominent

 

Alarm type

ExtDev

Notes

From RTE v34.11.3 emergency messages are handled as alarms: to disable the new handling act on bit 0 of the predefined variable sys_cfg.

From RTE v34.24.0 the alarm is also used for the EC2-A drive.

Alarm related to the SPIMD20 or EC2-A device connected on the EtherCAT network.

From RTE 34.28.04 the device name is EC Drive

 

  