Alarm information:

Cause

Absolute transducer battery signals alarm

<axis>

Axis number (1-32)

<name>

Device type name (IMD, EC2A).

From RTE 34.28.04, the device name is EC Drive

Output condition

Emergency: 0xFF80 0x01 0x0000482Dnn, where nn indicates axis number

Effect

Possibility of absolute quota information loss

What to do

Replace batteries

Alarm mask

am[<axis>].0

Alarm par prominent

Yes

Alarm type

ExtDev

Notes

Introduced in RTE v34.19.0.

From RTE v34.24.0 the alarm is also used for EC2-A drive.

From RTE v34.22.1 it is considered only as an alarm, and no longer as an alarm/warning.

Alarm related to IMD and EC2-X drives.

Whether or not this alarm can be cleared is affected by bit 17 of sys_cfg. If the bit is 0, the alarm is issued only once at switch on and therefore erasable. If, on the other hand, it is 1, the alarm is not erasable.

From RTE 34.28.04 the device name is EC Drive

 

  