Abilitare JavaScript per vedere questo sito.

[FileInfo]

FileName=aAxX.dcf

FileVersion=1

FileRevision=0

EDSVersion=4.0

Description= parameter file for Axes X drive on my machine

CreationTime=08:00AM

CreationDate=25-12-2006

CreatedBy=Claus Santa

ModificationTime=08:30AM

ModificationDate=25-12-2006

ModifiedBy=Natale Babbo

 

[ManufacturerObjects]

SupportedObjects=xx

1=0x2F00

2=0x261B

3=0x2618

4=0x2619

5=0x2617

6=0x261A

7=0x261F

8=0x261E

9=0x261C

10=0x290A

11=0x230A

12=0x231C

13=0x231E

14=0x2F13

15=0x2F06

16=0x2F09

17=0x2C02

18=0x2300

19=0x3001

20=0x2c2a

; parametri per pannello operatore (can)

21=0x5FFF

22=0x5FFE

23=0x5FE6

; progammazione pdo

24=0x1400

25=0x1600

26=0x1800

27=0x1A00

; numero di ws  e chiusura password ( DEVONO rimanere gli ultimi)

28=0x2801

29=0x2006

 

[2F00]

ParameterName=cs00 speed control config.

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=5

AccessType=rw

PDOMapping=1

ParameterValue=4

 

[261B]

ParameterName=dr27 DSM rated torque [nm/10]

ObjectType=0x07

DataType=0x03

LowLimit=1

HighLimit=32767

AccessType=rw

PDOMapping=1

ParameterValue=92  ;   <<<<<<<<<<<

 

[2618]

ParameterName=dr24 DSM rated motor [rpm]

ObjectType=0x07

DataType=0x06

LowLimit=0

HighLimit=32000

AccessType=rw

PDOMapping=1

ParameterValue=3000  ;<<<<<<<<<<<<<

 

[2619]

ParameterName=dr25 DSM rated motor frequency [Hz/10]

ObjectType=0x07

DataType=0x03

 

LowLimit=0

HighLimit=16000

AccessType=rw

PDOMapping=1

ParameterValue=500  ; <<<<<<<<<<<<<<

 

[2617]

ParameterName=dr230 DSM rated current [a]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=710

AccessType=rw

PDOMapping=1

ParameterValue=92   ;  <<<<<<<<<<<

 

[261A]

ParameterName=dr26 DSM EMK voltage constant [V]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=500

AccessType=rw

PDOMapping=1

ParameterValue= 1 ; <<<<<<<<<<<<<<<<<<<

 

[261F]

ParameterName=dr31 DSM winding inductance   [mH/100]

ObjectType=0x07

DataType=0x03

LowLimit=1

HighLimit=50000

AccessType=rw

PDOMapping=1

ParameterValue= 1 ; <<<<<<<<<<<<<<<<<<<

 

[261E]

ParameterName=dr30 DSM winding resistance   [ohm/1000]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=50000

AccessType=rw

PDOMapping=1

ParameterValue= 1 ; <<<<<<<<<<<<<<<<<<<

 

[261C]

ParameterName=dr28 DSM motor current for 0 speed [A/10]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=500

AccessType=rw

PDOMapping=1

ParameterValue= 1 ; <<<<<<<<<<<<<<<<<<<

 

[290A]

ParameterName=Fr10 load motor depending parameter

ObjectType=0x07

SubIndex=0

DataType=0x03

ParameterValue=1

 

[230A]

ParameterName=op10 maximum reference forward [rpm/0.125]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=32000

AccessType=rw

PDOMapping=1

ParameterValue=24000

 

[231C]

ParameterName=op28 acc. time forward [s/100]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=30000

AccessType=rw

PDOMapping=1

ParameterValue=0

 

[231E]

ParameterName=op30 dec. time forward [s/100]

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=30000

AccessType=rw

PDOMapping=1

ParameterValue=0

 

[2F13]

ParameterName=cs19 absolute torque limit [Nm/100]

ObjectType=0x07

DataType=0x06

LowLimit=0

HighLimit=1000000

AccessType=rw

PDOMapping=1

ParameterValue=1000 ; <<<<<<<<<<<<

 

[2F06]

ParameterName=cs06 KP speed

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=32767

AccessType=rw

PDOMapping=1

ParameterValue=800  ; <<<<<<<<<<<<

 

[2F09]

ParameterName=cs09 KI speed

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=32767

AccessType=rw

PDOMapping=1

ParameterValue=300 ; <<<<<<<<<<<

 

[2C02]

ParameterName=do02 condition 2

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=42

AccessType=rw

PDOMapping=1

ParameterValue=4

 

[2300]

ParameterName=op00 reference source

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=9

AccessType=rw

PDOMapping=1

ParameterValue=2

 

[3001]

ParameterName=EC01 encoder 1 (inc/r)

ObjectType=0x07

DataType=0x03

LowLimit=-32768

HighLimit=32767

AccessType=rw

PDOMapping=0

ParameterValue=1024 ; <<<<<<<<<

 

[2C2A]

ParameterName=do42 inverter output

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=255

AccessType=rw

PDOMapping=0

ParameterValue=4

 

[5FFF]

ParameterName=CAN_Baud

ObjectType=7

DataType=5

LowLimit=0x0

HighLimit=0x6

DefaultValue=1

AccessType=rw

PDOMapping=0

ParameterValue=7

 

[5FFE]

ParameterName=SAVE_CAN_Baud

ObjectType=7

DataType=5

LowLimit=0x0

HighLimit=0xff

DefaultValue=0

AccessType=rw

PDOMapping=0

ParameterValue=1

 

[5FE6]

ParameterName=PDIN1_Cycle_Time

ObjectType=7

DataType=6

LowLimit=0x0

HighLimit=0xffff

DefaultValue=25

AccessType=rw

PDOMapping=0

ParameterValue=25

 

[1A00]

SubNumber=3

ParameterName=1st transmit PDO Mapping

ObjectType=9

 

[1A00sub0]

ParameterName=number of mapped objects in PDO

ObjectType=7

DataType=5

LowLimit=0

HighLimit=8

AccessType=rw

DefaultValue=2

PDOMapping=0

ParameterValue=3

 

[1A00sub1]

ParameterName=1st object to be mapped ; ec31. QUOTA ASSE

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x301F0120

 

[1A00sub2]

ParameterName=2nd object to be mapped ; sy51 STATUS WORD

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x20330110

 

[1A00sub3]

ParameterName=3rd object to be mapped ; ru0 Invert state

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x22000110

 

[1800]

SubNumber=3

ParameterName=1st transmit PDO Parameter

ObjectType=0x09

 

[1800sub2]

ParameterName=transmission type

ObjectType=0x07

DataType=0x05

LowLimit=254

HighLimit=254

AccessType=ro

DefaultValue=254

PDOMapping=0

ParameterValue=0

 

[1800sub3]

ParameterName=inhibit time

ObjectType=0x07

DataType=0x06

LowLimit=0x0000

HighLimit=0xFFFF

AccessType=rw

DefaultValue=0x012C

PDOMapping=0

ParameterValue=19

 

[1800sub1]

ParameterName=COB-ID used by PDO

ObjectType=0x07

DataType=0x07

LowLimit=0x00000000

HighLimit=0xFFFFFFFF

AccessType=rw

DefaultValue=0x00000182

PDOMapping=0

ParameterValue=0x00000182

 

[1600]

SubNumber=4

ParameterName=1st receive PDO Mapping

ObjectType=0x09

 

[1600sub0]

ParameterName=number of mapped objects in PDO

ObjectType=7

DataType=5

LowLimit=0

HighLimit=8

AccessType=rw

DefaultValue=2

PDOMapping=0

ParameterValue=3

 

[1600sub1]

ParameterName=1st object to be mapped ; ps24 ????

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x33180120

 

[1600sub2]

ParameterName=2nd object to be mapped ; sy50 Control word

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x20320110

 

[1600sub3]

ParameterName=3rd object to be mapped ; op03 Reference Setting

ObjectType=7

DataType=7

LowLimit=0x20000010

HighLimit=0x5EFF0010

AccessType=rw

PDOMapping=0

ParameterValue=0x23030110

 

[1400]

SubNumber=2

ParameterName=1st receive PDO Parameter

ObjectType=0x09

 

[1400sub2]

ParameterName=transmission type

ObjectType=0x07

DataType=0x05

LowLimit=0

HighLimit=255

AccessType=rw

DefaultValue=254

PDOMapping=0

ParameterValue=0

 

[1400sub1]

ParameterName=COB-ID used by PDO

ObjectType=0x07

DataType=0x07

LowLimit=0

HighLimit=0xFFFFFFFF

AccessType=rw

DefaultValue=0x00000202

PDOMapping=0

ParameterValue=0x00000202

 

[ManufacturerObjects]

SupportedObjects=1

1=0x290A

; queste imposizioni DEVONO essere le ultime

; reset password

 

[2801]

ParameterName=UD01 bus password input

ObjectType=0x07

DataType=0x03

ParameterValue=100

 

[2006]

ParameterName=SY06 Inverter address

ObjectType=0x07

DataType=0x03

LowLimit=0

HighLimit=239

AccessType=rw

PDOMapping=0

ParameterValue=2

 

  