Date: 01 July 2010

Os: 13.19.1028

RoboxLib: 3.05.0000

Derived from: RTE 33.21

Note: suite with >= RDE3.8.3

Note: suite with >= RC3E v33.3.7

Note: suite with >= RPE v1.3.3

build 10

IMPLEMENTATION(OS) : REPORT : expanded to 2048 entries

CORRECTION(OS) : EtherCAT : Ethercat cable reconnection management - feature no longer operational in 33.22.9

VARIATION(OS) : EtherCAT : reduced rule extension time to the bare minimum in case of Ethernet cable disconnection on the robox control side.

build 9

IMPLEMENTATION(OS) : SDO to EtherCAT SoE devices.

Changed the meaning for of sub index when communicating via SDO to SoE type devices.

CO_SDO

Device command

CO_WOBJ

Shell command

CO_ROBJ

Shell command

CO_SEND_SDO

R3 function

CORRECTION: MVA_TO_N

In the case of HOLD, the code M_REACHED nwas being erroneously output when HOLD was set until the axes were stopped.

CORRECTION: BCC MONITOR LIST

0 was always being returned as the number of monitors/oscilloscopes present on commands.

FIX: TASK RELOAD

Improved handling of task_reload function(see live changes)

build 8

IMPLEMENTATION: SYS_FLAG

Added bit .12 (0x1000) to enable warning in report of each message sent in serial

FIX: TASK RELOAD

Strengthened in-memory loading especially reloading tasks that make use of OB (direct or indirect)(see live changes)

build 7

IMPLEMENTATION: OVERRIDE.CFG

Management of the /FA/OVERRIDE.CFG file.

IMPLEMENTATION: ETH_INFO

Added directive (device command) to display the status of an Ethernet channel.

IMPLEMENTATION: SER_INFO

Added directive (device command) to display serial channel status.

build 6 build 5 build 4

FIX: SERIALS

Auto error correction on read in case of errors.

IMPLEMENTATION: SOE

Added EtherCAT SoE (Servodrive Over EtherCAT) transducer and actuator type management.

build 3

IMPLEMENTATION: MVA_ZC

Added management of bit 0x1000 (bit.12). It is used only for cycle of 0 to end of strokes.

CORRECTION: MVA_ZC at end of strokes.

Used as return speed in end of strokes the one defined in stru_mvzc.velZC instead of stru_mvzc.velPos used in the other operational modes.

build 2

CORRECTION: MVA_ZC to end of strokes.

Fixed error on axis test "on end of strokes" based on real speed

VARIANT: HIDRIVE COE

Added specific handling as EtherCAT (coe).

VARIANT: POWER SET-FAULT RESET

Previously the fault reset command from PowerSet was generated only when at least one AM bit was reset.

So if there were multiple alarms in the stack that used the same AM bit the alarm reset on powerset was generated only when the last alarm in the stack was cleared.

Now the alarm reset on powerset is generated as with each reset command.

FIX: FLOAD RAM DISK

Also updated the last access time for a file loaded in ram disk

build 1

FIX: F_READ_TABLE

Fixed error introduced in version 33.21.12 that caused in file not to be read if relying on local variables

build 0

FIX: R RR SR

Removed limit on number of volatile registers to 65535

IMPLEMENTATION: SER_MOD

Managed code 18 to have ASCII-LF type communication without handshaking

VARIANT: SERIAL INSTRUCTIONS

Changed diagnostic if using serial instructions with the number of a non-existing serial. Previously ILLEGAL FUNCTION alarm was generated now ILLEGAL ARGUMENT alarm is generated.

VARIANT: CO_PAR_DOWNLOAD

Automatically disabled communication alarms during download in case a NMT status other than operational is imposed

CORRECTION: serial

Improved handling of serials above number 4 - now serials with number from 1 to 31 are manageable

VARIANT: CO_PAR_UPLOAD

The stored value is now imposed in the generated dcf file with the data type specified in the eds file and not with the value actually received from SDO

 

  