Date: May 12, 2014
Bios: 2.3.1, Os: 14.4.6, RLib: 4.3.1, RLibpp: 2.0.0, MiniXML: 1.0.0
Derived from : RTE 34.13.12
Note: available for controls with PPC-G2 cpu and for controls with PPC-P2020 cpu.
Note: suite with >= RDE3.11.5
Note: suite with >= RC3E v33.5.14
Note: suite with >= RPE v1.5.5
build 3
•IMPLEMENTATION : EthernetIP: Added fw version and revision data (viewed remotely on master)
•CORRECTION : TASK TOO LONG ALARMS : Improved task handling type Oscilloscope Manager.
•IMPLEMENTATION : RESTARTED: Implementation bit integer parameter to tell if a task has been reloaded.
•IMPLEMENTATION : SYNC_RESTART: implementation bit integer parameter to tell when a request for a synchronous restart is present.
•CORRECTION : R(555) : was fouling R(555) by executing a RESTART_POINT instruction.
build 2
•VARIANT : variant text alarm 90
•IMPLEMENTATION : Drive Phase PHOTO and CYCLES OF 0: final implementation integration 2 level.
•CORRECTION : Alarm 90 generation : Fixed error that could generate alarm improperly.
build 1
•IMPLEMENTATION : DEVICE_PN_FAMILY, DEVICE_PN_MODEL, DEVICE_SN: added integer parameters in which to read the Part Number and Serial Number.
build 0
•IMPLEMENTATION : error setting B.P. on NULL or DUPLICATE line - SYS_CFG: Added BIT 8 to immediately trigger diagnostic by imposing a B.P. on a non-existent or mulitple-defined step.
•CORRECTION : HISTORICAL ALARM : Fixed the problem that occurred when enlarging the number of stored alarms.
•CORRECTION : POWER_SET Can - uRIO(AS3039.001) : Fixed the problem of going to power when both can/coe axes and axes associated with uRio are present in the same powerset.
•CORRECTION(OS): EthernetIP : Set correct data of device vendors d, type hw, model, sn... .
Immediate generation of configuration alarm on configuration error (e.g., different buffer size).
Configuration alarm generation after 120 seconds if no query from master has occurred.
•CORRECTION : FIRST_TIME() on RC(32), T(32)
•CORRECTION : BP on Step task R : fixed error introduced in 33.18.1 that caused BP not functioning on execution of some user task step.
•CORRECTION(OS): ETHERCAT configuration : fixed fieldbus-EtherCAT variable names containing multiple spaces as separator