Meaning of REGISTERS assuming "idx" as the index of the integer register specified in the FULL_DIAGNO_R idx command in the configuration file.
Register |
Value |
Description |
---|---|---|
R(idx+0) |
|
Reserved |
R(idx+1) |
|
Reserved |
R(idx+2) |
|
Reserved |
R(idx+3) |
|
Channel type can (4-->Board RBXM ; 12 uRmc2/3) |
R(idx+4) |
|
Installed software version |
R(idx+5) |
|
Release of installed software |
R(idx+6) |
|
Communication states •0x1 RX buffer ready to be read from EthIP •0x2 RX buffer ready to be written to EthIP •0x40 in 1 EthIP communication active |
R(idx+7) |
|
Number of Ethernet IP packets sent |
R(idx+8) |
|
Number of Ethernet IP packets received |
R(idx+9) |
|
EthIP board WatchDog counter |
R(idx+10) |
|
Configuration steps |
R(idx+11) |
|
Ethernet IP error code - see table below |
R(idx+12) |
|
Ethernet IP connection additional information error code - see table below |
R(idx+13) |
|
EthIP status of LR/LG leds (see table led) |
R(idx+14) |
|
EthIP status of NSR/NSG leds (see table led) |
Meaning of REGISTERS assuming "idx" as the integer register index specified in the DIAGNO_R idx command in the configuration file.
Register |
Value |
Description |
---|---|---|
R(idx+0) |
|
Communication states •0x1 RX buffer ready to be read from EthIP •0x2 RX buffer ready to be written to EthIP •0x40 in 1 EthIP communication active |
R(idx+1) |
|
Number of Ethernet IP packets sent |
R(idx+2) |
|
Number of Ethernet IP packets received |
R(idx+3) |
|
EthIP board WatchDog counter |
Ethernet Ip Error Code (FULL_DIAGNO_REG+11)
Dec |
Hex |
Meaning |
---|---|---|
0 |
0x0 |
No error |
1 |
0x1 |
Error in 'connection service' |
2 |
0x2 |
Resource for service not available |
3 |
0x3 |
Illegal parameter value |
4 |
0x4 |
Error in path segment |
5 |
0x5 |
Unknown path destination |
6 |
0x6 |
Transfer performed only partially |
7 |
0x7 |
Connection lost |
8 |
0x8 |
Unsupported service |
9 |
0x9 |
Invalid data attribute found |
10 |
0xA |
Attribute list error |
11 |
0xB |
Already in idle state |
12 |
0xC |
Unable to execute the requested service in the current state |
13 |
0xD |
Already existing object |
14 |
0xE |
Attribute not editable |
15 |
0xF |
Violation in permissions/privileges |
16 |
0x10 |
Conflict in device state |
17 |
0x11 |
Data too large |
18 |
0x12 |
Fragmentation of the primitive value |
19 |
0x13 |
Not enough data |
20 |
0x14 |
Attribute not supported |
21 |
0x15 |
Too much data |
22 |
0x16 |
Object does not exist |
23 |
0x17 |
Fragmentation service not active |
24 |
0x18 |
No attribute data stored |
25 |
0x19 |
Storage operation failure |
26 |
0x1A |
Failure 1 routing |
27 |
0x1B |
Failure 2 routing |
28 |
0x1C |
Attribute list missing |
29 |
0x1D |
Invalid attribute list value |
30 |
0x1E |
Integrated service error |
31 |
0x1F |
Vendor-specific error |
32 |
0x20 |
Invalid parameter |
33 |
0x21 |
Already written |
34 |
0x22 |
Received invalid response |
37 |
0x25 |
Segment key error |
38 |
0x26 |
Invalid path size |
39 |
0x27 |
Unexpected attribute list |
40 |
0x28 |
Invalid id |
41 |
0x29 |
Part not editable |
42 |
0x2A |
General failure G2 |
Ethernet connection Ip additional information error code (FULL_DIAGNO_REG+12)
Dec |
Hex |
Meaning |
---|---|---|
0 |
0x0 |
Connection OK |
256 |
0x100 |
Error in the connection in use |
259 |
0x103 |
Transport trigger not supported |
262 |
0x106 |
Property conflict |
263 |
0x107 |
Connection not found in target application |
264 |
0x108 |
Invalid connection type |
265 |
0x109 |
Invalid connection size |
275 |
0x113 |
Connection no longer available |
276 |
0x114 |
VendorId or Product code error 1 |
277 |
0x115 |
VendorId or Product code error 2 |
278 |
0x116 |
Revision mismatch |
279 |
0x117 |
Invalid connection |
280 |
0x118 |
Invalid configuration |
281 |
0x119 |
Connection not open |
282 |
0x11A |
Object out of connection |
517 |
0x205 |
Error in parameter |
789 |
0x315 |
Invalid segment |