Alarm information:

Cause

Unable to return the PROF.INT board to operation.

Possible misconfiguration

<code>

Error code:

8 = Configuration (number of 32-byte blocks) received from DP master different from that set in pfb.cfg file

9 = Profibus communication management hardware error (SPC3)

Output condition

Bit 10 of sys_flag_2 is set to 1

Effect

Profibus management disabled

What to do

With version of RTE less than or equal to v34.27.01 turn the control off and on again to try to re-enable communication.

With version of RDE greater than or equal to v34.27.02 is reset if the cause does not persist

Alarm mask

am[50].24

Alarm par prominent

No

Alarm type

Autodia