Alarm information:
Cause |
Emergency from drive |
<axis> |
Axis number (1-32) |
<name> |
Device type name (TWn or AXM) |
<code> |
Fault code (TWn): •0x2110 = Overcurrent/power short-circuit/power module fail Fault code (AXM): •0x2110 = Overcurrent/power short-circuit/power module fail •0x2120 = Overcurrent/power short-circuit/power module fail on double power bridge hardware |
Output condition |
|
Effect |
Power drop |
What to do |
Check the status of the drive |
Alarm mask |
am[<axis>].9 |
Alarm par prominent |
No |
Alarm type |
|
Notes |
As of RTE v34.13.8, emergency messages related to PHASE drives TWn and AXM are handled as alarms. Alarm related to PHASE drives connected on field bus. Refer to the drive manual for more information. Performance is enabled by indicating in RTE design configuration (axes, transducer/actuator) the TWn or AXM family drives |