Alarm information:
Cause |
No communication with Sinamics. Possible causes: •If the auto restart function is enabled, the error may be generated when the interface is holding restart due to a download of the new configuration •There is no configuration in the CU, the status of the exchanged data of the drive is "acyclic data exchange" |
<cde> |
Cyclic data exchange |
<axis> |
Axis managed by REB that generated the alarm |
Output condition |
|
Effect |
Power set power drop |
What to do |
Check network |
Alarm mask |
am[34].10 |
Alarm par prominent |
Yes |
Alarm type |
|
Notes |
Introduced in RTE v34.18.7. Alarm related to Sinamics drives connected on EtherCAT bus. Refer to the REB(Robox Control Board AS3031.xxx) board manual for more information. Performance is enabled by indicating in RTE design configuration (axes, transducer/actuator) the Sinamics family drives |