Alarm information:

Cause

Error generated when a new SINAMICS project is loaded from the STARTER

<axis>

Axis number (1-32)

Output condition

 

Effect

 

What to do

Since some parameters of the SINAMICS are read only once at switch on from the EtherCAT interface, in order to avoid applying new parameters and settings to the interface, a restart of the CU is requested

Alarm mask

am[<axis>].10

Alarm par prominent

No

Alarm type

ExtDev

Notes

Introduced in RTE v34.24.7.

Alarm related to Sinamics drives connected on EtherCAT bus.

See the REB board manual (Robox Control Board AS3031.xxx) for more information

NOTE: Performance is enabled by indicating in the RTE project configurator (axes, transducer/actuator) the Sinamics family drives.

 

  