Date: January 26, 2007
Os: 13.2.242
RoboxLib: 2.1.0
Derived from: RTE 33.1.5 synchronous to 32.7.0
Note: suite with >= RDE3.3.0
Note: suite with >= RC3E v33.1.4
build3
•CORRECTION
Interference problems with using interpolating type movements simultaneously on different axes groups. Alarm 9903 was being generated ...
•CORRECTION
Fixed rule execution enabled with INT_AFTER
•CORRECTION
MVA_TO_N_V
Avoided some multiple sampling mission time adaptations that could cause the function to return with code -6 (mission impossible)
•IMPLEMENTATION(os)
Improved TCP/IP communication
build2
•IMPLEMENTATION
Added in profibus and devicenet the possibility to treat received data as I16 instead of the current default of U16. This performance is achieved by using the keywords R_16_I and NVR_16_I
•CORRECTION
Enabled asynchronous rule execution at time
build1
•CORRECTION
Added Task creation for interrupt handling on slot 0 and improved handling in case of multiinterrupts on the same slot (CPU)
build0
•IMPLEMENTATION
Enabled Instruction SER_485_TX_STS
•IMPLEMENTATION
Added DF1 communication management.
Uses DF1.CFG configuration file.
In case of error it generates alarm "9206 DF1 configuration fault line(%d)". Still use the report
Added on SYS_FLAG bit 0x40 to enable report DF1 messages received
bit 0x80 to enable report DF1 messages sent
•IMPLEMENTATION
Added in report info of baud and members on serials
•VARIANT
Add to LICENSE directive the -D parameter for visualization of desired license information
•CORRECTION(os)
Fixed traffic light handling that could cause DEAD-LOCKS under certain conditions.