Please enable JavaScript to view this site.

Date: 19 December 2006

Os: 13.1.832

RoboxLib: 2.1.0

Derived from: RTE 33.0.4 synchronous to 32.6.2 dated December 18, 2006

Note: suite with >= RDE3.3.0

Note: suite with >= RC3E v33.1.3

build5

VARIANT

Set as default value (in case of parameter loss) for POS_THR the numeric value 0.01 instead of 10

build4

VARIANT

The deceleration on the end of strokes is stored when the stopping phase begins. The acceleration used is also recalculated so as to avoid speed jumps when changing accel. (from large value to small value!)

build3

IMPLEMENTATION

Added SLOT directive nSlot offset [LEN m ] [-D|-H|-B] [-M n]

VARIANT

Change double2all na_double

build2

IMPLEMENTATION

Management of phase execution on rte.cfg

IMPLEMENTATION

Loading and execution of RPE

VARIANT

In MV_TO_N_V the feedrate is used to normalize the initial velocity equal to vi_entrant = vi_axis / Fr

VARIANT

Inserted OSFM 13.1.638 which REQUIRES and SUPPORTS BIOS 1.1.0. Note: this bios REQUIRES this OSF or higher (Sistem Call x atomicity)

build1

CORRECTION

Power Set

Axis enable management : sometimes axis enable would fail and correct diagnostics would not be issued

CORRECTION

Ladder

Fixed random problems accessing the monitor.

CORRECTION

Avoided restarting tasks unnecessarily to avoid filling task management waiting for queues.

CORRECTION

Avoided waiting if channel disabled or queue error.

CORRECTION

Avoided loops due to errors on queues.

CORRECTION

Problem after 32 uploads would freeze communication trask

build0

CORRECTION

Ladder was not working correctly on some block instructions or multiple outputs if one of the outputs was a timer and/or counter ()

CORRECTION

On interpolated moves the initialization steps were being executed multiple times unnecessarily()

IMPLEMENTATION

Handling ascii command execution in rte.cfg

IMPLEMENTATION

Handling phase execution of commands in rte.cfg

IMPLEMENTATION

Added bit handling SYS_FLAG.4 to enable in the alarm

9900 Illegal Arg. A:aaa T:tt St:sss

instead of the argument number 'aaa' a number related to the routine that generated the alarm.

CORRECTION

In the ladder the keyword AM(n) did not work if used in comparison and/or math blocks

CORRECTION

With ladders it could happen that some units (timer, or real ) were aligned odd causing an alignment error on first use. To remedy this all variables are rounded to 8

CORRECTION

Instruction FDIR did not return all filenames

CORRECTION

To solve the problem that RDE going ONLINE with debugging reports that the file may not be the right one since CRC(on control) is no longer calculated for ELF files, I use TCLOCK instead

You must also have the updated compiler version to work.

IMPLEMENTATION

Power_set

Added -E parameter on GLOBAL_POWER_FEEDBACK to enable feeback handling on front.

Default is on level.

Note: in case you select front and give power request with feedback already present the power enable command is not generated!!!

VARIANT

Power_set

The fault state of the can is now assumed to be no feedback from drive, regardless of the status of bit 0 and bit 1

VARIANT

Power_set

Enable management is enabled only after global power feedback arrives

 

  

Keyboard Navigation

F7 for caret browsing
Hold ALT and press letter

This Info: ALT+q
Page Header: ALT+h
Topic Header: ALT+t
Topic Body: ALT+b
Contents: ALT+c
Search: ALT+s
Exit Menu/Up: ESC