Date: November 5, 2013
Bios: 2.3.0, Os: 14.4.1, RLib: 4.3.1, RLibpp: 2.0.0, MiniXML:1.0.0
Derived from : RTE 34.11.12
Note: available for controls with PPC-G2 cpu and for controls with PPC-P2020 cpu.
Note: suite with >= RDE3.11.3
Note: suite with >= RC3E v33.5.12
Note: suite with >= RPE v1.5.0
build 3
•CORRECTION: LOV : corrected error that could return LOV variables of type Axes group , POINT_L, PATH and/or from OB impossible to access. The phenomenon occurred if you reloaded (multiple times) the first task that contained the variable in question.
•CORRECTION: ALARMS : corrected alarm number 663 in 683 and 664 in 684.
build 2
•CORRECTION : LADDER - LIVE changes : Fixed error in allocations when a new variable is added in live mode.
•IMPLEMENTATION : BCC COMMAND 706 : Added bcc 706 (ProcessFlashInfo) command to be able to handle ladder file loading directly from editor (Icon in ladder editor tool bar).
•CORRECTION : LADDER : Problem that arose starting with version 34.11.8
The problem occurs if online changes are made on a timer and counter and the changes are loaded more than once without applying them. The effect is alarms on unmodified ranks using the same timer and the no longer functioning of the timer.
•VARIANT : ELF : Increased the maximum number of managed sections from 500 to 1000.
build 1
•VARIANT(os) : TCP UDP ETHERNET : Various fixes and implementations.
build 0
•CORRECTION : LADDER : added TON and TON timer reset management (restarts counting)
•VARIANT(os) : HEAP : Changed heap memory manager. It is faster and there is possibility to manage more heap.
•CORRECTION(os) : MEMORY USE WITH ETHERCAT : Improved management memory use by ethercat configurator manager.