Date: March 31, 2006
Os: 12.14.0000
RoboxLib: 1.04.0000
Derived from: RRT 32.1.11
Note: needs LOADER.BIF
Note: suite with >= RDE3.1.3
Note: suite with >= RC3 v32.0.14
Note: suite with >= CODM0602.UFW
build1
•CORRECTION
Made read-only parameters cannot be written using ascii directive
•IMPLEMENTATION
Parameters NUM_R, NUM_RR, NUM_SR, NUM_NVR, NUM_NVRR, NUM_NVSR
•IMPLEMENTATION
Alarms handling lost PLL from channel can- alarm communication code 3
•IMPLEMENTATION
Added -REPn to ADD command of power_set
•IMPLEMENTATION
Directives for PowerSet PS_LIST PS_INFO PS_STATUS
•CORRECTION
Fixed problem when enabling/disabling/re-enabling a drive
•CORRECTION
Made "same data" diagnostics not be given when S_REF , T_REF or POS_REF is set to OFF
•IMPLEMENTATION
New command in power set DIAGNO_REG idxR.
description : definition of an array of R destined to store salient data for power management.
syntax : DIAGNO_REG idxR
idxR : beginning index of the array of R
description : R(idxR+0) = power going enable from alarms (0 --> not enable)
R(idxR+1) = group forward power enable (from instruction ) (0 --> not enable)
R(idxR+2) = Request for going to power
R(idxR+3) = Series Global Power Feedback (0--> no feedback)
R(idxR+4) = mask of individual components of Global Power Feedback
R(idxR+4).0 --> first definition of GLOBAL_POWER_FEEDBACK in the RTE.CFG file
R(idxR+4).1 --> second definition of GLOBAL_POWER_FEEDBACK in the RTE.CFG file
R(idxR+4).2 --> ......
R(idxR+5) = feedback mask of individual CAN channels (if any) Axes are represented as logical axes (LAM)
R(idxR+6) = GLOBAL_POWER status (0 --> no_power)
build0
•IMPLEMENTATION
NEG and NOUT ladder function
•IMPLEMENTATION
Starting in RTE with ADV pressed displays the operation counter of the main
•CORRECTION
MV_TO movement in case of target inversion and lowering of vmax below current speed
•CORRECTION
Avoided associating a slot interrupt task if interrupt handling already in use by OS