Code: |
AS + 735 |
Symbolic: |
bccSysReportCmd |
This command will send a command to system report on the remote device. Request has following parameters:
Offset |
Type |
Label |
Description |
---|---|---|---|
0 |
U32 |
FLAGS |
Command flags: 0x00000001 Clear report 0x00000002 Set system report size 0x00000004 Set 'up to fill' mode 0x00000008 Set 'round' mode 0x00000010 Set acquisition mask |
4 |
U32 |
SIZE |
New system report size (no. of item), if bit enabled |
8 |
U16 |
AMSK |
New system report acquisition mask. |
On success, a bccAck is received with no data.
On failure, a bccNack is received. Specific errors:
NACK code |
Description |
Extra data |
---|---|---|
nackIllegalArgs |
Illegal parameter |
U16 What illegal: 1=Flags 2=Size 3=Mask
|
nackReadOnly |
System report is readonly and is not modificable. |
|