Code: |
AS + 319 |
Symbolic: |
bccSafeReleaseVar |
This command will release the value of a variable (for example release the state of an input channel). Request parameters are the following:
Offset |
Type |
Label |
Description |
---|---|---|---|
0 |
U32 |
VAR SETID |
Variable set identification |
4 |
VARID |
Variable identification |
On success, a bccAck is received with no data.
On failure, a bccNack is received. Specific errors:
NACK code |
Description |
Extra data |
---|---|---|
nackReadOnly |
Variable read-only or predefined |
|
nackIllegalArgs |
Illegal arguments |
U16 What illegal: 1=Type 2=Index 3=Address 4=Repeat counter 5=Bit index 6=Size |
nackCantRelease |
Variable value cannot be released |
|
nackIllegalVarsetId |
Illegal variable set identification |
|
nackNotInitialized |
Variable is not initialized |
|