Please enable JavaScript to view this site.

Code:

427

Symbolic:

bccOscWd

This message will refresh transmission grant time (oscilloscope watchdog) for specified variable oscilloscope (or all oscilloscope of the owner) on the connected device. Request parameters are the following:

Offset

Type

Label

Description

0

U32

OWNER

Owner identification ID

4

U32

ID

Oscilloscope identification ID, or 0xFFFFFFFFF for all owner's oscilloscope.

8

U32

WDT

Watchdog time [ms]

The message has no reply.

Notes:

If an oscilloscope watchdog is expired and it's definition is yet valid, a bccOscWd will automatically restart the oscilloscope (like bccOscStart).

 

  