Code: |
427 |
Symbolic: |
bccOscWd |
This message will refresh transmission grant time (oscilloscope watchdog) for specified variable oscilloscope (or all oscilloscope of the owner) on the connected device. Request parameters are the following:
Offset |
Type |
Label |
Description |
---|---|---|---|
0 |
U32 |
OWNER |
Owner identification ID |
4 |
U32 |
ID |
Oscilloscope identification ID, or 0xFFFFFFFFF for all owner's oscilloscope. |
8 |
U32 |
WDT |
Watchdog time [ms] |
The message has no reply.
Notes:
•If an oscilloscope watchdog is expired and it's definition is yet valid, a bccOscWd will automatically restart the oscilloscope (like bccOscStart).